Local Level Lab

Airborne measurements. Open methods.

Why two ESA settings abstain

The four zero-removal flat-disc fits all stopped after 43–45 evaluations, well below the frozen 200-evaluation ceiling. Each reports “no positive predicted decrease” and fails the unchanged fresh-position stability check. The two fixed starts and two IMU error conventions reached nearly the same training cost, but agreement between starts is not the declared convergence test.

Error convention Start Evaluations Fresh north-position RMS change Frozen RMS limit
Increment 0 45 1.5032 mm 1.0000 mm
Increment 1 45 1.5032 mm 1.0000 mm
Point 0 43 1.5032 mm 1.0000 mm
Point 1 43 1.5032 mm 1.0000 mm

The saved fresh stationarity values are about 1.82×10⁻⁶, below the declared 10⁻⁴ stationarity limit. The failed position check is therefore specific and reproducible; simply granting more evaluations would not address the reported stopping reason. The original four outcomes remain nonpassing, and both zero-removal matched settings remain unresolved.

A saved-derivative check narrows the numerical issue. At each final fitted point, a bounded linear correction predicts a cost reduction of about 3.107×10⁻⁶ from a cost near 10,428. Computing that reduction directly and as −2r·(Jd)−|Jd|² agrees within 0.0001% in all four cases. The last attempted full correction instead increased* the actual cost by about 1.86–1.88×10⁻⁵, and the solver rejected it. Thus, rounding in the predicted-cost subtraction does not explain the failed full step. The remaining issue is the local model's accuracy along that correction, or how the trust step moves through the curved, bounded fit. This is a diagnostic from the sealed residuals, Jacobians and step histories; it makes no new fit. The saved-only report records each fit-artifact hash, both reduction calculations and the original failed label. It can be regenerated with PYTHONPATH=analysis ~/venv/bin/python analysis/tests/run_numerical.py --workers 1 --threads 1 -- ~/venv/bin/python -m lll.esa_matrix_stopping_geometry --root ..

Any later attempt to recover these settings needs a separate, source-bound solver qualification that tests curved bounded valleys against known answers, with the same scientific inputs and physical bounds. It must preserve the four original failures, charge new work separately, and apply the same numerical acceptance rule to all three physical models. A looser stopping rule cannot be inferred from the close agreement of these starts.

A generated known-optimum check passed all eight cases with both the existing trust region and a centered objective solver. SciPy TRF reached nearly exact costs yet failed the unchanged position check on six curved cases. Flight-scale qualification remains open before any newly frozen observed comparison.

Full matrix result · Every fit · Frozen plan.