Local Level Lab

Airborne measurements. Open methods.

Why the recorded-data method did not qualify

The 24-fit pilot used three previously selected aircraft recordings. Every fit finished and saved a prediction for receiver positions that had been held out of calibration. That establishes that the software ran; it does not establish that the numerical answer was stable or that its prediction was physically adequate.

Only 7 of 24 fits passed the frozen numerical stopping checks. Of the other 17, two failed the stationarity check before a fresh probe could be made. Fifteen completed a fresh probe but failed its combined check. All fifteen exceeded the relative cost-change limit of 10⁻⁸. Five also exceeded the stationarity limit of 10⁻⁴, and three also exceeded the position-change limit (1 mm RMS or 1 cm maximum on any axis). Ten failed only the cost-change part of that combined check. A saved-only audit reproduces these overlapping counts from the sealed fits, records their hashes and makes no new model evaluations. Reproduce it with ~/venv/bin/python -m lll.ilvis0_observed_method_diagnosis. A failed stopping check is preserved even when its forecast is close to another forecast.

Two of the six matched recording/cut sets exceeded the 0.1 m development path-agreement scale: the inner cut of the 2010 northern recording differed by up to 0.752 m, and the inner cut of the 2015 southern recording by up to 0.320 m. All six matched training-cost ranges were under 0.01. The small cost ranges therefore do not guarantee matching later paths. The other four cuts met the path scale, including cuts with nonstopping fits. The saved path-pair identities show that the 2010 maximum is between the two optimizers at the same start; the 2015 maximum is between two starts of SciPy TRF. Both kinds of numerical variation matter.

The two differing cuts also have the widest spreads in fitted receiver/IMU time offset: 6.0 ms and 11.2 ms. The four other cuts range from effectively zero to 0.056 ms. The audit records all six pairs. This association points to timing as a useful next diagnostic; it does not show that timing alone caused the forecast differences, because other fitted parameters changed too. The subsequent fixed-endpoint timing check replayed all eight selected solutions exactly. It found only a 0.004 ms time-offset difference in the 2010 maximum path pair, versus 11.237 ms in the 2015 pair. Timing alone therefore cannot be presumed to explain both. The later calibration-swap check found that swapping a single parameter group sharply worsens training fit while the complete paired solutions retain near-equal costs. Their calibration changes compensate one another.

The seven stopping fits have later horizontal RMS errors from 0.45 to 9.76 m and later height RMS errors from 0.07 to 5.05 m. All seven put Z-axis gyro bias, Z-axis gyro gain and the gravity correction at their allowed bounds. Those bounds are study assumptions, not measured instrument limits. Passing a numerical stopping check therefore does not by itself establish an adequate physical calibration or an accurate forecast.

The saved accuracy audit applies the unchanged position-error screen from the transfer study to all 24 forecasts. All 24 meet those limits. The 17 nonstopping fits retain their failed numerical labels, and the two cuts outside the forecast-agreement scale remain open.

The current gates must not be loosened simply to raise the pass count. Next, use the saved costs, fresh probes, bound activity and forecast errors to separate two questions: whether the cost-change tolerance is tighter than the numerical precision that the recorded problem supports, and whether the two differing forecasts reflect materially distinct feasible solutions, including their fitted timing offsets. Any changed stopping rule needs an independent generated control and a new finite recorded-data study. The original 80 aircraft fits and this pilot keep their saved labels.

This is a method diagnosis for one specified-field globe candidate. It is not a globe-versus-flat result, a background-field estimate or a calibrated scientific detection.