Two-start generated method check
The faster tangent calculation did not pass its new two-start qualification gate. All 12 paired tasks completed and passed their individual numerical and physical checks. Across the six model/processing settings, only the two flat settings passed the complete start-equivalence rule. The four globe settings failed. This is a software-method result, not an Earth-model comparison.
The forecasts themselves agreed closely: the largest cross-method difference among the selected starts was 1.75 × 10⁻⁹ m, versus the predeclared 0.01 m limit. The failed rule also required matched training costs to agree within 1 × 10⁻⁸ relative. Their largest relative difference was 1.18 × 10⁻⁵ (an absolute difference of 6.18 × 10⁻¹⁷ in the study's cost units). In the still-globe setting with profiled upstream removal, the two methods selected different primary starts. Both selected forecasts were still within 1.15 × 10⁻⁹ m. These small absolute differences explain the failure; they do not change its predeclared outcome.
| Physical setting | Removal profiled? | Gate result | Main reason |
|---|---|---|---|
| Globe with specified field | No | Fail | Training-cost tolerance |
| Globe with specified field | Yes | Fail | Training-cost tolerance |
| Globe with zero field | No | Fail | Training-cost tolerance |
| Globe with zero field | Yes | Fail | Training-cost tolerance and start choice |
| Stationary disc | No | Pass | All checks passed |
| Stationary disc | Yes | Pass | All checks passed |
The study used 240 of 4,824 permitted native calls and finished in about 651 seconds. Its sealed record verifies all 12 results, source and environment bindings, and charge accounting. It used generated observations only; no NASA or ESA recording or protected confirmation group was read. The original observed exact-start failure remains unchanged, and the established wide calculation remains the operational method.
The frozen rule compares near-minimum forecasts across methods. A future rule must also bound forecast variation within each method's near-minimum starts before it can establish start-choice stability. Any revised cost tolerance needs independent numerical justification and a new prospective freeze; this completed study cannot be rescored into a pass.
The frozen plan and method definition specify the tested question. The packaged receipt and evidence are in the study record.