The trial calculation preserved all eight generated fits
All eight fits reproduced the original solver records and forecasts exactly. The proposed steps, accepted and rejected decisions, final parameters and stopping checks matched in each case. Seven fits passed the numerical stop. The specified-field globe fit on a zero-field history retained its failure.
| Calculation | Full tangent calls including forecasts | Value-only calls |
|---|---|---|
| Sealed reference | 290 | 0 |
| Value-only trial check | 127 | 258 |
The method skipped 163 full tangent calculations, a 56% reduction in that work. The study did not retime the sealed reference fits, so the reduction is a count of expensive calculations. The aircraft point check supplies individual CPU timing. The cases here were chosen to exercise the solver's rejection and stopping behavior, so they do not estimate typical savings on aircraft data.
The frozen plan compares two complete four-model settings. An independent read of the closed results matched every fit and forecast against the frozen inputs and verified all 385 charges. No aircraft fit was started. The next gate is an equal-limit recorded-data check with one passing control and the saved zero-field disc stopping failure.