Local Level Lab

Airborne measurements. Open methods.

Value-only and tangent calculations agree at four aircraft points

Both calculations produced exactly the same coordinates, residuals and packet-boundary counts at all four saved points. The tangent calculation also reproduced the saved fitted residuals and the cost of the fresh correction.

Recorder and model Saved point Tangent CPU Value-only CPU Speed ratio
IMU8, zero-field disc Endpoint 52.02 s 0.45 s 116×
IMU8, zero-field disc Fresh correction 36.70 s 0.76 s 49×
IMU8, specified-field globe Endpoint 52.62 s 0.74 s 71×
IMU21, specified-field disc Endpoint 38.70 s 0.79 s 49×

Timing uses process CPU time, excluding compilation and artifact writes. These are individual evaluations. The existing solver also needs derivatives for accepted steps and its final stopping probe. A matched full-fit study must verify that checking proposed steps with the faster calculation preserves the solver path, stopping results and forecasts at equal iteration limits.

The frozen check completed all three tasks and charged exactly eight native calls. It started zero fits and used no later receiver positions. The original zero-field disc stopping failure remains in the record. See the sealed evidence for the paired arrays, timing observations, source and accounting.