Local Level Lab

Airborne measurements. Open methods.

Test both ends of the measured force interval under one gain

Use all 991 original windows, both packet clocks and the four shape and field candidates. Compare the measured accelerometer bounds with the saved predicted force bounds for onboard and carrier-phase motion. Use the same nonnegative gain range of 0–15% as the previous lower-bound check. This gain is shared across the axes and all windows within one recording and candidate.

If one gain makes the measured and scaled predicted intervals overlap in every training window, retain the interval of such gains and use its smallest value. Otherwise find the gain that minimizes the maximum separation between the measured and scaled predicted intervals. Give an upper and lower bound on that minimum. The two possible gap types move in opposite directions as gain increases, so their crossing can be bracketed by bisection. This is a uniform force gap in measured units. It gives no estimate of the component due to receiver error, calibration, attitude or motion.

Use the training gain and gap allowance unchanged on later windows. Report the additional gap required at the fixed gain and the number of later cases outside the training allowance. Run separate profiles for each receiver motion input and a profile requiring the same gain and allowance to cover both inputs. The joint case is a sensitivity check across two possible paths that share many errors. Overlap is a necessary check on the saved intervals. It does not establish one trajectory or one time offset that satisfies the entire recording.

Limit this calculation to 24 closed profiles, 52 bisection steps per profile and one numerical thread. Read only saved force bounds. Use zero position solves, inertial fits or gyro observations. Freeze source and inputs before running, then verify the saved result by exact replay.