Local Level Lab

Airborne measurements. Open methods.

A small gain change cleared the training force lower bounds

All four candidates passed the training inequalities after applying one common gain correction per recorder and candidate. Every correction was below 1%, within the existing 15% allowance. The corrections were then held fixed for the later comparison. All four cases still cleared the IMU21 lower bounds. All four had a small number of later violations on IMU8.

Recorder Candidate Training gain Later violations at zero gain Later violations with the gain held fixed
IMU8 Globe, specified field 0.385% 414 6 / 1,158
IMU8 Globe, zero field 0.243% 201 6 / 1,158
IMU8 Disc, specified field 0.964% 1,085 14 / 1,158
IMU8 Disc, zero field 0.135% 89 8 / 1,158
IMU21 Globe, specified field 0.162% 18 0 / 708
IMU21 Globe, zero field 0.155% 18 0 / 708
IMU21 Disc, specified field 0.106% 18 0 / 708
IMU21 Disc, zero field 0.071% 12 0 / 708

The largest remaining excess on IMU8 was 0.00772 m/s². These are overlapping windows evaluated under two clocks and three GPS processing choices. The row counts describe checks on two recordings. They cannot establish accuracy or independent replication across flights.

The frozen test uses only a lower bound from the recorded accelerometer and an upper bound from the GPS-predicted force over the same intervals. Passing leaves the full force and orientation history unresolved. The IMU8 violations show where this particular gain choice and GPS path bounds fall short. A calibrated comparison still needs receiver, calibration and trajectory errors handled jointly, along with the remaining orientation ambiguity. The matched lower-bound check abstains.

Force averages · Full receipt.

env PYTHONPATH=analysis ~/venv/bin/python analysis/tests/run_numerical.py --workers 1 --threads 1 -- ~/venv/bin/python -m lll.ilvis0_matched_force_gain replay