Local Level Lab

Airborne measurements. Open methods.

ESA primary-start sensitivity

The verified 24-case substitution study did not qualify. In three complete groups, the wide and faster methods chose different starts by training cost. This post-run check compares their saved forecasts; it does not refit or change the failed gate.

Model Processing Error policy Wide cost gap Faster cost gap Maximum forecast difference
sphere_rotating 0 reported-short-v1 1.37371e-08 1.00574e-07 1.15007e-07 m
sphere_still 0 reported-short-v1 0.000328541 0.000229836 7.91329e-05 m
sphere_still 1 reported-persistent-v1 4.63799e-07 1.67638e-08 1.34585e-05 m

These are numerical sensitivity measurements, not a new Earth-model comparison or a basis for changing the 0.01 m gate.

Verified paired report · Machine-readable diagnostic.