Local Level Lab

Airborne measurements. Open methods.

Withheld prediction errors and receiver-reported precision

This saved-data check uses the three recordings already selected for the retrospective prediction pilot. It ran no new model fits. Each setting chose a numerical start using the earlier training cost alone; later errors did not choose the start.

Result: all saved epochs matched that recording’s primary receiver precision report. Of 36 model, timing and processing settings, 28 had a numerically qualified start and eight did not. The receiver’s stated precision is its own estimate, not a measured truth error. Dividing prediction error by that estimate describes scale; it does not establish statistical significance.

Model Qualified / 12 Passed earlier uncalibrated accuracy screen Median later north / east / height RMS (m) Median error / receiver-reported sigma, north / east / height
globe with specified field 9 / 12 7 1.10 / 1.34 / 8.54 4.2 / 4.2 / 11.0
globe with zero field 9 / 12 0 305.17 / 391.37 / 7.24 611.3 / 871.5 / 10.8
stationary disc 10 / 12 0 148.72 / 566.43 / 35.75 350.6 / 1619.2 / 32.8

In the nine numerically qualified specified-field globe settings, a straight time trend accounts for a median 96.9% north, 95.7% east and 97.4% height of the centered later-error variation. This is a retrospective description across three recordings. It does not show that a trend could be predicted from earlier observations, or identify whether IMU drift, motion, timing or receiver error caused it.

These are descriptive medians across different recordings and settings, including models that may be wrong. Individual settings and numerical abstentions remain in the verified report. The per-setting autocorrelation fields there are Pearson correlations between lagged slices; the earlier pilot error-structure report uses a different full-window normalization. Do not compare those numbers directly. The reported receiver precision does not include IMU, calibration, model or shared navigation errors. This study therefore makes no positive scientific decision and does not calibrate an absolute goodness-of-fit test.