Can earlier forecast error predict later error?
A single multiplier does not describe these three development recordings. The frozen study completed all 48 planned fit starts. Thirty-four passed their numerical stopping checks; fourteen did not. None was lost to an execution error. After choosing each start by its earlier training cost, eight of twelve clock/processing settings have a passing fit at both prediction cuts. The other four abstain.
Each matched setting compares two forecasts of the same length from one recording. One fit uses the first third of receiver positions and forecasts the next third. A separate fit uses the first two thirds and forecasts the final third. The scoring positions were opened only after the forecasts were saved. The table gives the range of later error divided by earlier error among matched settings; 1 means equal root-mean-square (RMS) error.
| Recording | Matched settings | North | East | Height |
|---|---|---|---|---|
| A: southern IMU8 survey | 2/4 | 1.49–2.60× | 0.64–0.71× | 0.97–0.99× |
| B: northern IMU21 survey | 4/4 | 0.44–0.53× | 0.26–0.83× | 2.40–2.43× |
| C: southern IMU21 survey | 2/4 | 2.23–4.09× | 0.33–0.69× | 2.58–2.67× |
The pooled medians—1.01× north, 0.67× east and 2.42× height—hide these opposing patterns. In B, north error shrinks while height error grows; in C, north and height both grow. The clock and processing settings reuse each recording, so eight matched settings are not eight independent flights. Three settings abstain because the later-cut fits fail numerical checks; one abstains at both cuts. All 34 passing fits have three to five normalized calibration parameters at their declared bounds. These are fit diagnostics, not measured sensor limits or evidence of an instrument defect.
These three recordings do not calibrate a single earlier-to-later RMS multiplier as an uncertainty limit for the archive. They do not rule out a richer error law that accounts for time, direction, motion and fitted calibration. The next gate is an error model estimated from earlier observations and checked on independent flight groups, with physical-position and future receiver-report coverage assessed separately. Fourteen nonpassing numerical fits and active calibration bounds remain part of that assessment.
The study used only three previously selected NASA development recordings, the specified-field globe candidate, and their prepared inertial and primary receiver streams. It made no new globe/disc decision and read no reserved ESA confirmation flight. The original 53-stretch model comparisons are unchanged.
Verified study result · All twelve settings · All 48 fit starts · Recording identities and selection · Frozen plan