Fresh generated range check: execution record
The frozen plan fixed 256 new generated histories, the unchanged 15-state changing-drift law, a wider 4.2 standardized-error threshold and a one-failure-per-stratum gate before this cohort ran. One numerical worker used one thread and completed 256/256 tasks in 1,094 seconds, with zero technical errors and no native aircraft calculation. A source/environment freeze, charge journal, task receipts and reboot recovery policy were in place before launch; no recovery task was needed.
The saved-only audit recomputes every later score from its forecast and residual. It found 1/128 whole-history exceedance without the generator's vibration and 0/128 with it. The exact 97.5% upper failure bounds are 4.28% and 2.84%, respectively, so the new generated gate passed. The median final per-coordinate half-width is 29.57 m.
This result qualifies the new threshold only for the specified generated histories. The earlier 3.635-threshold study remains a failed gate. Neither study establishes coverage for a real aircraft or makes an Earth-model decision. The seven reserved ESA flight groups remain unopened.