Clean 100 Hz propagation control
The independent analytic generator supplied exact motion and no sensor or receiver error. The same local IMU integrator used in the generated coverage study ran for 120 seconds at 100 Hz.
| Physical vibration | Maximum north error | Maximum east error | Maximum up error |
|---|---|---|---|
| off | 0.000208 m | 0.000003 m | 0.000001 m |
| on | 0.000323 m | 0.000002 m | 0.000002 m |
The largest clean integration error is below 0.0004 m. The four saved generated exceedances have absolute prediction errors of 0.15–0.67 m at their maxima. Thus clean 100 Hz integration error alone does not explain those misses. This control does not diagnose changing sensor noise, conditioning or actual aircraft data.