Receiver quality does not give a simple explanation for the height pattern
The saved-only audit compared the two sealed ESA fits' first 600 receiver reports with their fitted height errors. It verified that each raw height difference is forecast height minus the saved receiver height. No fit, later receiver report or reserved flight group was opened. The two IMU error laws give practically identical associations.
| Saved training quantity | Raw height difference versus PDOP | Raw height difference versus satellite count |
|---|---|---|
| Ordinary correlation | +0.759 | −0.676 |
| Correlation of report-to-report changes | −0.286 | +0.219 |
| Correlation after removing a cubic time trend from each series | −0.328 | +0.417 |
The ordinary correlations reverse sign after either time check. The raw height difference has 0.659 m RMS. The height error after the declared whitening has a much weaker ordinary correlation with PDOP (−0.184), and its cubic-time-adjusted correlation is +0.005. Its corresponding correlation with reported height precision is only +0.031 after that adjustment.
PDOP ranges from 1.11 to 1.53, satellite count from 17 to 19 and reported height standard deviation from 0.042 to 0.060 m in these saved rows. The receiver reports vertical speeds from 1.64 to 4.65 m/s, so the interval contains substantial climb motion. A shared time trend can make receiver quality and fit error appear related even when their short-term changes do not agree. Removing a cubic trend is a sensitivity check, not a physical model of that climb.
This audit does not rule out receiver error. It shows that the saved quality indicators alone do not provide a stable attribution for the persistent fitted height residual. Motion, timing, calibration and error-law misspecification remain possible. The complete-fit generated pilot is running separately; aircraft forecast uncertainty is still unqualified.