Local Level Lab

Airborne measurements. Open methods.

Earlier-origin prediction diagnostic

Question

Does the specified-field globe fit trained on the first 400 receiver reports of the already opened ESA development recording predict reports 400–519 with physically adequate position errors? This is a development diagnostic of forecast growth. It is not an independent flight, an Earth-model decision or a calibrated uncertainty test.

The 120-report horizon was chosen after earlier forecasts from this recording were examined. Results cannot independently validate that horizon. Preserve the completed 600/200 and 800/400 results unchanged, including their failures.

Design to freeze before fitting

The test uses one earlier origin on one development flight. It may expose when the height error begins, but it cannot identify whether the cause is sensor error, aircraft motion, calibration, receiver error or timing. The seven reserved ESA groups stay closed until a separately qualified method, error range and decision policy are frozen.

The saved-input preflight verifies 400 training reports, 120 withheld reports and 155,868 IMU packets through the prediction end. The new study identity is esa-rolling-origin-400-development-v1-20261115. Source-bound tests and a separately frozen recovery policy must pass before that study starts.