Earlier-origin fit result
The first 400 receiver reports in the already opened ESA development window were fitted under both preregistered IMU error laws. The following 120 receiver positions were absent from the fit inputs. Both numerical tasks sealed and passed. They used one start each and eight evaluations each; neither fit had an active calibration bound.
| Assumed IMU error law | Training cost | Evaluations | Active bounds |
|---|---|---|---|
| Recorded increments | 5.102913 | 8 | 0 |
| Point rates | 5.102906 | 8 | 0 |
The nearly equal costs do not identify which error law describes the aircraft. These are fits to the first 400 positions, not tests on the next 120. A separate early-only conditioning calculation must close before those later positions are scored. No physical adequacy or Earth-model decision follows from this fit result.
The verified study is data/esa-rolling-origin-400-development-v1-20261115.
Its manifest SHA-256 is
ed1c026bbcb4d280913d0ef58280967dcfa7cc784f73b32773182db00f0864cb
and its completion seals summary SHA-256
8f5a8cd721873c8ee9d0cb18fa20e194b97efd1746d27cc96a1c2b4b5c1b5da3.