Local Level Lab

Airborne measurements. Open methods.

Refitting the ESA rate alternatives does not fix prediction accuracy

All six training-only fits converged under the unchanged bounds and stopping rule. Both original linear-point fits reproduced their saved fitted parameters and forecasts exactly. The three rate interpretations were fitted separately under each of the two original IMU error laws, using only the first 800 receiver positions. The 400 later positions were opened only after all six forecasts sealed.

Rate interpretation Fits converged Training horizontal error, RMS Later horizontal error, RMS Later height error, RMS Preset accuracy screen
Original linear points 2/2 39.96 m 249.41 m 4.35 m Fail
Left sample hold 2/2 39.56 m 247.89 m 4.41 m Fail
Right sample hold 2/2 37.69 m 240.37 m 4.55 m Fail

Values shown to two decimals agree for the increment and point error laws; the machine-readable result preserves all six separate values, vertical errors, maxima, evaluation counts and stopping records. The fits took eight or nine evaluations each. None ended at an active calibration bound; the largest absolute normalized parameter was 0.489 on a scale bounded by ±1. That removes boundary saturation as the immediate reason for these six numerical outcomes, without establishing that the calibration or observation model is correct. Every training and later horizontal RMS exceeds the predeclared 10 m screen. The screen is a descriptive physical-accuracy rule, not a calibrated confidence interval.

The right-hold calculation has the smallest error in this one development recording. That does not identify the instrument's actual sampling rule: choosing from later receiver errors would use the withheld answers to select the method. The three methods differ by less than 10 m in later horizontal RMS after refitting, while all miss by more than 240 m. The large mismatch is therefore not resolved by rate assignment alone. The present scientific decision is abstain.

This was one previously selected ESA development interval, not six flights or independent confirmation. It used three workers at one numerical thread each, sealed 6/6 passing technical tasks in 5,935.76 seconds, and charged the frozen ceilings of 4.2 million native calls and 270 billion packet/query visits. Those are reserved upper bounds, not a count of operations actually needed. No original source file or one of the seven reserved ESA confirmation groups was opened during fitting.

The next development gate is to locate the error common to all three rate conversions—initialization, calibration, force model, or receiver-error assumptions—using saved residuals and separately qualified controls. Do not open the seven reserved groups or promote an Earth-model comparison from these failed accuracy screens.

Frozen observed plan · Generated software check · Earlier fixed-point check · Comparison with the earlier accurate fit.

Completed observed-study manifest: fabb0ef004ce452a7a0b0a14ac71c307b350d3b9b4d25ca8bc8545598f75c2ba. Summary: 47f01b56eda5710d0698f26a4727b12945abfcaa8f8fe3be50ff5a8df0fc03a7.