Fitted calibration uncertainty does not explain the ESA height miss
The corrected one-task study completed. It generated the missing native forecast derivative at the saved fit and verified that all 1,200 generated positions exactly match the sealed forecast. All 26 whitened training Jacobian columns replay the saved fit within the fixed tolerances. The training rank is 26/26, and the local parameter step remains inside the original bounds. Its largest normalized correction is about 1.7 × 10⁻⁸, so the predicted path barely changes.
| Later GPS check, 400 reports | Fixed parameters | Local fitted-parameter uncertainty added |
|---|---|---|
| Horizontal prediction RMS | 2.849 m | 2.849 m |
| Height prediction RMS | 11.881 m | 11.881 m |
| Height reports inside nominal 95% marginal interval | 25/400 | 26/400 |
| Reports inside nominal 95% three-axis region | 37/400 | 40/400 |
| Largest predicted height standard deviation | 3.556 m | 6.495 m |
The local covariance grows, but the persistent height error remains far outside it. This rules out the omitted local linear parameter variance alone as an explanation under the declared error law. It does not rule out nonlinear calibration uncertainty, another error law, timing or processing effects, or a mismatch in the physical observation model.
The machine report verifies the sealed study, forecast and original later receiver rows. This one segment's reports are strongly correlated, so 26/400 is descriptive, not a binomial coverage estimate. The run used one thread and completed in 366 seconds. The original plan and two preserved technical failures record the full sequence. No reserved ESA group was opened. The observed error law and uncertainty coverage remain unqualified; the scientific decision is abstain.