A shared weak calibration direction in the generated fits
A saved-fit audit examined the two closed generated fits without refitting or opening aircraft data. Each fit has 26 calibration parameters and a complete numerical solution, but its fitted physical path fails the original accuracy screen.
| Generated error law | Local Jacobian rank | Weakest / strongest singular value | Reciprocal weakest singular value |
|---|---|---|---|
| Increment | 26/26 | 0.0000210 | 2.99 normalized parameter units |
| Point | 26/26 | 0.0000211 | 3.00 normalized parameter units |
The weakest direction mixes gyro X and Y gain, gravity adjustment, and vertical accelerometer bias. Its axis is nearly identical in the two fits: the sign-independent direction similarity is 0.99999. The reciprocal singular value describes local sensitivity under the assumed whitening; it is not a measured instrument uncertainty or a valid nonlinear confidence interval. Several fitted parameters reach their allowed bounds.
Full algebraic rank therefore does not imply that training positions pin down every calibration combination tightly enough for an accurate later path. The same route was used under both error laws, so their similar weak axis is not independent replication. This audit does not prove that this one direction caused either path miss. The next generated control should vary that combined calibration direction through the full nonlinear forward model and measure its effect on the training and later path, with all original accuracy failures preserved. No Earth-model decision follows.