Short-timescale IMU changes in recorded and generated data
The known-answer generated fits leave much larger training errors than the ESA development fit. This saved-only comparison checks whether their IMU inputs have similar short-timescale behavior. It uses the first 600 seconds of each generated recording and the existing 800-second ESA training-rate study. Both sample at about 300 Hz. Their durations differ, so this is a descriptive comparison, not a matched noise estimate.
For each axis, the calculation takes three equally spaced rate samples and removes their straight-line trend. The table gives the RMS of that contrast. The shortest span is about 0.0067 seconds; the longer span is about 2 seconds.
| Recording | Span | Gyro Y, rad/s | Force Z, m/s² |
|---|---|---|---|
| ESA development | 0.0067 s | 0.02396 | 2.388 |
| Generated, increment-error truth | 0.0067 s | 0.000101 | 0.00346 |
| Generated, point-error truth | 0.0067 s | 0.0000413 | 0.00141 |
| ESA development | 2 s | 0.02317 | 2.254 |
| Generated, increment-error truth | 2 s | 0.00278 | 0.0268 |
| Generated, point-error truth | 2 s | 0.00279 | 0.0264 |
The full saved report gives all six axes at four spans. The recorded short-span variation is much larger than either generated stream, despite the recorded fit's much smaller whitened training error. At two seconds the comparison varies by axis: for example, the generated X-gyro contrast is larger than the recorded one. A single scale factor cannot make the two rate-variation patterns match.
These body-axis changes include aircraft maneuvering, vibration and any onboard processing. They do not isolate IMU sensor noise or explain the later height-prediction failure. The ESA rate study is read from its sealed historical artifact; its source is not replaced with today's library code. No original recording, later receiver value or reserved confirmation flight was opened, and no fit was repeated. The scientific decision remains abstain.