The generated path screen is tighter than its declared noise
The saved eight-case audit used the cohort's earlier-only forecast covariance and known generated route. Under the assumed noise law, even with calibration fixed, the square root of expected squared horizontal error over the later 300 seconds is 17.39 m for each case. The inherited deterministic screen requires 0.1 m. The expected error scale is about 174 times that screen.
| Generated law | Cases | Raw fitted path error | Earlier-conditioned center error |
|---|---|---|---|
| Increment | 4 | 109–197 m | 20–30 m |
| Point | 4 | 67–182 m | 7–66 m |
Ranges show horizontal RMS across the four noise seeds per law. Conditioning on earlier receiver observations improves every case, but none of the saved centers is within the inherited 0.1 m screen. The 17.39 m figure is a second-moment scale, not a deterministic minimum or a measured aircraft error. It excludes uncertainty in fitted calibration; the actual raw-path miss can be much larger. The eight cases share one route. Even if these eight cases were independent draws from a fixed population, eight successes would give only a 31.2% one-sided 95% upper bound on failure probability; their shared route narrows the inference further.
The clean-data accuracy rule is therefore unsuitable as the sole pass gate for these noisy generated forecasts. This does not explain the excess raw-path error or validate the assumed covariance on real aircraft. A new, separately frozen qualification must judge physical prediction against its declared noise and calibration uncertainty, with absolute adequacy and empirical coverage checked separately. The frozen eight-case failures and all earlier results remain unchanged. No new fit or aircraft data were used; the scientific decision remains abstain.