How far the linear forecast follows a calibration change

On ESA recording 187, the scalar integrator reproduced the sealed nominal forecast within one nanometre. It then propagated six finite changes along the three calibration combinations least constrained by the earlier fit. All changes stayed inside the original bounds. The fitted onboard-removal parameter started at its lower bound, so the checks moved inward.

Weak direction Step in normalized calibration coordinates Earlier RMS error in the linear approximation Later RMS error in the linear approximation Later error as a share of displacement
1 0.01 0.0015 mm 0.0063 mm 0.018%
2 0.01 0.072 mm 0.257 mm 0.64%
3 0.01 0.066 mm 0.199 mm 0.37%
1 0.10 0.148 mm 0.634 mm 0.18%
2 0.10 7.22 mm 25.7 mm 6.5%
3 0.10 6.56 mm 19.9 mm 3.7%

Increasing the step tenfold increased the error by about a factor of 100 on each ray. At the larger step, the largest single-query error was 34.2 mm. The step sizes use the normalized fit coordinates. They describe how far the calculation moved within the fit's permitted range, without assigning a probability to that move.

This checks one saved fit and three individual directions. Combining calibration changes can produce different errors. An aircraft decision still needs a bound across the feasible earlier-fit region for every model and a supported law for forecast errors that also change over time.

One of one tasks passed. There were seven value sweeps, zero new fits and zero reads of withheld receiver positions or reserved flights.

Fixed study plan · Original tangent replay

The closed study ID is esa-tangent-remainder-v1-20261118. Its manifest SHA-256 is ea8916a3dc0229d7001f0db42bc1a3f37f470df81d57746f3b32a34757331e62. The sealed finite-changes.json stores all six signed displacement paths, their actual parameter steps and the RMS and maximum errors. Its SHA-256 is b710c4df6c6a68eba85510d07f08ae9cffc009b51eba87b7ed24db7b315d1c83.