An earlier Nuuk correction improves later range agreement

A correction learned from the first part of the development flight lowered the later aircraft carrier residual from 4.38 cm to 1.92 cm RMS. It helped on each of the three later 30-second intervals. Subtracting the entire ground residual gave 3.58 cm RMS. Frozen plan

Later range residual No ground correction Full ground subtraction Earlier multiplier held fixed
Ionosphere-free combination 4.38 cm 3.58 cm 1.92 cm
L1 band 6.83 cm 4.62 cm 3.65 cm
L2 band 9.24 cm 6.64 cm 5.83 cm

The multiplier was 0.581 for the combined bands. It was estimated from 11 earlier intervals. The three later intervals shared no epochs with those used for estimation. The interval containing the known aircraft clock step and the transition into the later group were left out. There were no broadcast ephemeris changes on the selected arcs. The aircraft path stayed fixed for every comparison.

The later improvement shows that a nearby ground receiver can help account for some of the range variation seen aboard the development flight. The numbers describe range residuals on one saved path. They leave the absolute aircraft coordinate error and the errors between ground samples unbounded. The one-second position benchmark still needs measurements at that cadence. The position projection finds that this earlier multiplier reduces the north and height adjustments implied by the later ranges and increases the east adjustment.

The study completed all 19 bounded operations. Eight focused tests passed. No receiver position or inertial model was refitted. No reserved recording was opened. Verified result