Local Level Lab

Airborne measurements. Open methods.

Gyro and accelerometer agree on much of the motion at two ground stops

The iMAR gyro predicted changes in the accelerometer's direction better than assuming the sensor stayed still. Agreement was much stronger at the first stop. The result supports a tilt contribution to the large logged rate variations even while the receiver reported low ground speed.

The fixed check divided both previously selected stops into complete one-second averages. It then used the original gyro timestamps to predict how each earlier accelerometer direction would appear later. No offset or sensor-axis alignment was fitted. The table gives root-mean-square angular error in arcseconds, where 3,600 arcseconds equal one degree.

Stop Separation Pairs Error assuming no motion Error using the gyro
First 1 s 2,705 874 298
First 10 s 270 819 246
Second 1 s 1,843 239 189
Second 10 s 184 514 440

After removing the mean change from each series, the gyro reduced squared error by 88–92% at the first stop and 30–38% at the second. The centered direction changes had similarity 0.96 at the first stop and 0.59–0.61 at the second, on a scale where 1 indicates agreement in direction. All complete pairs were included. The two time scales reuse samples.

Accelerometer direction gives a tilt reference only when linear acceleration is small. It cannot detect turning about its own axis. Both channels also share the mounting and instrument processing. The check therefore leaves yaw, gyro-only error and absolute airborne prediction accuracy unresolved.

The closed task verified the original file hash and both selected time ranges. It decoded 1,365,152 intervals, used seven charged operations and ran zero Earth-model fits. No reserved group was opened. The summary receipt binds the full per-pair results to the frozen calculation.

Source and execution receipts · Verified reproduction bundle