Force magnitudes did not qualify the platform clock
All three planned excerpts reproduced their earlier byte probes and the 1,024 Hz relative clock. The first excerpt failed to identify a unique offset to the independently timed 10 Hz force record. The two later excerpts independently pointed to the same candidate, which is useful for checking the horizontal channels.
| Excerpt | Best correlation | Next separated peak | Candidate offset to UTC seconds |
|---|---|---|---|
| First, preselected anchor | 0.462 | 0.455 | 50,431.967 s |
| Second | 0.848 | 0.419 | 38,474.267 s |
| Third | 0.637 | 0.383 | 38,474.267 s |
The original timing plan required the first excerpt to exceed 0.70 with a lead of at least 0.10 over the next separated peak. Because it failed, the two later peaks remain a candidate hypothesis. The horizontal-channel check uses the saved excerpts to test that hypothesis independently of their total force magnitudes. The earlier decision remains a failed timing qualification.
The terminal receipt has SHA-256
89f55710675bf6f16e8413916581644ab6a267c276072fbf8e26b4dcb8b8df86.
It preserves all seven charged operations, three completed comparisons and
zero model fits. The machine evidence records the exact captured byte
hashes and keeps the source ranges in the local authorized data directory.
Future acquisition and analysis use the separate
bounded transfer workflow.
The portable evidence bundle
preserves the original frozen analysis and its charges.