Match the platform clock against the separate iMAR recorder

Two of three saved GIRAFE excerpts matched the iMAR accelerometer at the proposed clock offset. The middle excerpt fell short, so the proposed clock did not pass the frozen check.

Both instruments were on the same aircraft. The check used changes in total force magnitude after 1.1 seconds of averaging. GIRAFE observations had already suggested the offset. The iMAR observations did not select it.

Saved excerpt Correlation at proposed time Best nearby correlation Best shift
First 0.941 0.968 −0.1 s
Middle 0.116 0.284 +0.1 s
Last 0.957 0.957 0.0 s

All three nearby peaks occur within 0.1 seconds of the proposed time. The first and last track closely, while the middle peak is weak even at its best shift. The middle excerpt also shows smaller force changes, with roughly half the variation measured by iMAR over the same period. It matched the separate timed GIRAFE vertical output well after averaging. These results leave open whether platform motion or the different instruments' responses explains the disagreement. The candidate vertical channel gives the same overall pattern.

The single local task completed with 13 charged operations, zero native model fits and zero reserved-group reads. Absolute timing and gyroscope channel interpretation remain open. The verified score receipt contains all 41 shifts for each comparison.