Local Level Lab

Airborne measurements. Open methods.

Check the vertical sign in the saved GIRAFE prefix

The original comparison applied the recorded signs. On both blocks the time tags coincided at zero lag, but every tested lag gave about 19.64 m/s² RMS of vertical force disagreement. The size of that disagreement motivates a test of opposite vertical axes.

Use the same exact original file, processed prefix and two blocks. Before opening the force values, fix the test as original acceleration against the negative of processed z-acc. Keep the same 41 shifts, one-to-one timestamp checks, sign-independent time support and RMS threshold from the first plan. Estimate neither a gain nor an offset. Report the result as a follow-up prompted by the signed comparison on the same records.

Allow one local task on one thread, one scan of at most 240,000 records and 82 comparisons, with a 30-second limit. There are no model fits or new recording reads. A match would identify the export convention for these samples and leave airborne timing, attitude and horizontal forces unqualified.