Local Level Lab

Airborne measurements. Open methods.

The GIRAFE vertical timestamps and sign match in flight

The original and processed GIRAFE vertical acceleration values match exactly at the same GPS timestamps across both fixed airborne intervals. The processed column uses the opposite vertical sign. That sign and zero time shift were set using the recording-start check before comparing the airborne values.

GPS seconds of week Samples RMS at zero shift with reversed export sign Best RMS at any other shift
388215–388225 100 0 m/s² 0.02020 m/s²
388614–388734 1,200 0 m/s² 0.06416 m/s²

All 82 comparisons completed. Zero shift alone met the fixed threshold in both intervals. Nine software tests passed. There were zero model fits and zero reserved-flight reads.

The processed z-acc column adds no independent vertical measurements on these intervals. The identical time labels establish how to match the two files. The delay from physical motion to the shared samples and the accuracy of the separate horizontal force channels remain open.

Frozen comparison · Acquisition receipt · All scores and accounting