A fixed quartz alignment fails to carry across the development flight

An alignment learned from the first 240 seconds left 17.2–18.4 mm/s² RMS of northward disagreement on the following 144 seconds. That is about nine times the 1.894 mm/s² position-acceleration scale of the north–south path error that could span the carrier score gap. The two quantities have different time averaging. Their sizes show why this alignment supplies no useful motion bound for that path test. North–south sensitivity

Zero-field geometry used for the GPS force calculation First 240 s vector RMS Next 144 s vector RMS with earlier alignment Next 144 s north RMS Next 144 s vector RMS after fitting those same data
Globe 85.21 27.97 17.20 1.18
Disc 86.92 29.81 18.41 1.25

All errors are in mm/s². Both earlier fits choose +0.1 seconds, the edge of the tested clock grid. Both internal refits retain the same axis handedness and change the fitted orientation by about 28–29°. This change can absorb differences in time, platform motion or force response. The small error after refitting the check intervals leaves the earlier alignment unqualified.

The sixteen fixed 24-second supports are entirely within the original earlier receiver interval. The sealed result retains all clock alternatives, the saved selection and the six signed check residuals for each geometry. An independent calculation reproduced the reported errors. Thirteen software checks passed and all 17 charged operations completed. Zero Earth-model fits ran and no reserved flights were opened. Frozen plan · Saved results