Test whether the fitted calibration transfers across the development flight

Use all four sealed straight-course controls and all four sealed turn controls on the opened recording 187. Use the 400 earlier receiver reports of each control, excluding the 120 reports scored by the original position forecasts. Confirm that the windows do not overlap one another or the window that set the calibration. Keep the existing 16 force supports, relative to the start of each window, and both 11- and 25-report averaging widths. Use the archived receiver export velocity present in all windows. Neither file selection nor averaging uses angular errors.

For each matched field and shape, transfer the exact 12-coordinate calibration from the corresponding all-source pooled fit. Keep those parameters fixed on every window. Start a separate orientation frame on each window by aligning the first eight force directions. Score the eight later directions with that orientation held fixed. Also run the nominal sensor calibration with the same starting-orientation rule. Compare angular RMS, paired shape ranking and changes from nominal. Keep results for all windows, including those with maneuvers or weak orientation information.

Freeze eight tasks, at most 13 packet passes per task with at most 121,000 intervals per pass, one numerical thread and a 180-second ceiling. No gyro or accelerometer calibration is re-estimated, no original data file is opened and no reserved group or original position holdout is used. The windows test within-flight transfer. A spread across them is a development diagnostic and does not establish a bound on independent-flight errors.