Local Level Lab

Airborne measurements. Open methods.

The direction forecast still favors the globe with all accelerometer axes free

The globe had smaller later force-direction errors in all 18 matched comparisons when each shape could fit all three accelerometer biases and all three gains from the earlier directions. With the specified field retained in the gyro, the later globe error was 0.004–0.020° RMS, versus 0.109–0.113° for the disc. The gyro increments stayed fixed.

Field setting, matched between shapes Later angular RMS, globe Later angular RMS, disc Globe advantage across paired settings
Zero field 0.293–0.306° 0.402–0.417° 0.109–0.112°
Specified field retained in gyro 0.004–0.020° 0.109–0.113° 0.093–0.107°
Specified field removed from gyro 0.294–0.307° 0.403–0.418° 0.108–0.112°

All 108 starts met the frozen projected-gradient criterion. The numerical library reported a line-search warning for 41 of them. Those flags remain in the results. The later RMS errors for the three starts at each setting agreed within 4.7 × 10⁻⁹°.

The calibration derivative has rank five after accounting for the unknown starting rotation. A common gain scale cancels when a force vector is converted to a unit direction. At least one calibration coordinate hit its working bound in 99 starts. With the specified field retained, the globe's earlier fit selected X biases from −0.009 to +0.015 m/s² and the disc selected +0.027 to +0.051 m/s². With the field absent from the gyro, both shapes selected the +0.10 m/s² X limit. These fitted values do not determine the instrument's true calibration.

This is an earlier-only calibration with eight later direction checks on one previously opened flight. The direction errors have no calibrated acceptance limit. The test leaves gyro gain, gyro bias, partial onboard field removal and independent-flight coverage open. All 108 starts and 6,659 actual training evaluations were retained. The prepaid ceiling was 21,600. No full inertial fit or reserved-flight data was used.

Reproduce the result

With the closed data/esa-direction-accel-calibration-v1 study restored, verify the saved scores and charges without fitting.

env PYTHONPATH=analysis ~/venv/bin/python analysis/tests/run_numerical.py \
  --workers 1 --threads 1 -- ~/venv/bin/python -m lll.esa_direction_accel_calibration report

Frozen design · All starts, boundary values and later errors