Local Level Lab

Airborne measurements. Open methods.

Fixed-endpoint timing check for the recorded-data pilot

Question

The 24-fit pilot completed technically but failed its numerical qualification. Two receiver cuts gave later paths that differed by 0.752 m and 0.320 m, despite close training costs. Both also have unusually different fitted receiver/IMU time offsets. At those exact saved parameter vectors, is the training calculation repeatable, and does moving only the time offset cross packet-interval boundaries or produce a non-smooth cost response?

This check diagnoses the existing fits. It does not refit them, change their stopping labels, inspect another flight, or test an Earth model.

Preselected comparisons

Use the two sealed fits that produced each maximum later-path difference, plus the same solver/start identities on that recording's outer cut as controls. The saved audit fixes these identities before any new calculation:

Recording Inner pair Outer control pair
2010 northern recording trust-region start 1; SciPy TRF start 1 trust-region start 1; SciPy TRF start 1
2015 southern recording SciPy TRF starts 0 and 1 SciPy TRF starts 0 and 1

There are eight fixed endpoints. Reuse the pilot's sealed training-only IMU and receiver inputs, model, timing convention, physical bounds and saved fit vectors. Withhold the later receiver positions throughout this calculation. Do not select endpoints by a new numerical outcome.

Calculation and finite allowance

At each endpoint, repeat the complete training prediction/tangent calculation twice at the same point. Then evaluate time offset at ±0.1 microsecond, ±10 microseconds, ±1 millisecond and ±4 milliseconds, using the existing lll.ilvis0_timing_probes calculation. Record actual cost, the analytic and finite-difference timing derivatives, packet-boundary crossings and receiver position changes. A perturbation outside the original parameter bounds or time support is an explicit diagnostic failure, not silently clipped.

Limit each endpoint to ten complete prediction/tangent calls and its exact packet-count × training-epoch charge. Across all eight endpoints the cap is 80 calls and 1,468,313,700 packet visits. Use four one-thread workers and a cooperative one-hour wall limit. Every call must be charged before execution. Preserve completed and failed tasks. A host interruption may recover only unfinished tasks under a separately finite, qualified task-level continuation; no completed endpoint may run again.

Interpretation

An exact same-point replay would establish repeatability at these eight points only. A boundary crossing or asymmetric finite difference would identify a specific timing mechanism worth testing in generated controls. Neither result by itself qualifies a changed stopping rule, proves the forecast is adequate, or supports a shape or rotation conclusion. Any revised method needs separate generated known-answer tests and a newly frozen recorded-data comparison before use in the broader roadmap.