Local Level Lab

Airborne measurements. Open methods.

Changing the direction of a rejected solver step

The trial passed 4 of 8 known-answer cases. The original solver and the earlier shorter-step trial passed the same four. All eight cases ran to a recorded result using 180 of the 320 allowed evaluations.

Known optimum Starts passed What happened
Upper limit 2 of 2 Recovered the known objective and passed the fresh position check.
Lower limit 2 of 2 Recovered the known objective and passed the fresh position check.
Interior 0 of 2 Both stopped before stationarity and failed the fresh position check.
Weakly constrained direction 0 of 2 The solver accepted 17 corrected steps across the two starts, and both still failed the fresh position check.

The correction uses the evaluated residual at a rejected point to estimate how the residual bends along the step. It then adjusts the direction within the same calibration bounds. The trial kept the stopping checks and acceptance limits fixed. All four failed cases also exceeded the allowed parameter and objective errors against the known answers.

The correction failed the gate for a generated flight-scale test. This trial used no aircraft measurements, and the two unresolved ESA development comparisons retain their recorded dispositions.

Frozen plan · Per-start results · Verification