Local Level Lab

Airborne measurements. Open methods.

Full-length clean IMU control

One source-bound software check propagated the noise-free rotating-globe stream through the same twenty-minute, 300 Hz known-correction predictor used by the noisy oracle. It used 360,000 IMU intervals, 1,200 receiver queries and one native call. The local test passed; the result, test report and source binding are hashed in the evidence receipt.

Error against generating truth Result
Later horizontal RMS 0.048 m
Later height RMS 0.060 m
Horizontal error at the training boundary 0.031 m
Horizontal error at the final query 0.064 m

The existing physical screens are 10 m horizontal RMS and 30 m height RMS. Thus the long ideal propagation is accurate for this preselected case. It does not explain why the matched noisy streams missed by 439–508 m with generating calibration supplied. The published covariance benchmark uses earlier receiver observations, while the noisy oracle does not. Compare those conditioning choices first; then use the same realized noise to separate gyro, accelerometer and changing-bias contributions. One clean case does not qualify all six noisy cases or establish aircraft uncertainty.

Frozen check · Result · Evidence receipt · Noise interpretation.