Local Level Lab

Airborne measurements. Open methods.

Check the noise approximation against nonlinear motion

2/4 settings pass the fixed finite check.

Input format Record length Matched controls passed Largest non-reversing error Result
Increments 2 min 16/16 0.000228481 m Pass
Rate points 2 min 16/16 0.000543138 m Pass
Increments 20 min 13/16 0.0909278 m Failed
Rate points 20 min 15/16 0.0506754 m Failed

Each control compares positive, negative and half-sized generated errors. The non-reversing part and change at half amplitude are checked against the larger of 1 mm and 1% of the predicted coordinate standard deviation. Seeds are shared across settings: these are not independent aircraft replications.

Known calibration, starting state and nominal geometry are supplied. Passing supports this finite noise approximation; it does not establish uncertainty after fitting unknown calibration, a global nonlinear bound, actual instrument noise or calibrated confidence. No aircraft fit, accuracy screen or reserved confirmation group changes.

Frozen plan · Construction checks · Noise benchmark · Next analyses.