Matched fitting and prediction check
The selective-precision calculation passed its first complete fitting and prediction comparison against the existing wide-precision calculation. All six generated two-minute cases passed. The cases cover three physical model settings and two processing settings. Each pair used the same simulated IMU measurements, receiver positions, optimizer, starting values and withheld prediction times. Only the tangent arithmetic changed.
Both fits in every pair converged and met the existing physical prediction screen. Across 714 matched forecast positions, the largest three-dimensional difference was 1.40 × 10⁻⁹ m, far below the frozen 0.01 m limit. The largest training-cost difference was 6.18 × 10⁻¹⁷. The study used 120 native calls and finished in 425 seconds, below its 2,412-call and two-hour ceilings.
This qualifies agreement of the tested software paths on these short generated cases. The earlier twenty-minute kernel check found 2.03–2.21 times lower native-call CPU time, but this fitting study did not measure whole-fit speed on long records. No observed aircraft data or protected confirmation data were used. This study makes no Earth-model decision and does not establish prediction-error coverage on aircraft observations.
The frozen plan, hashed results, source snapshot and charge records are retained here. A separate long-record fitting comparison is the next gate before replacing the current fitter.