Local Level Lab

Airborne measurements. Open methods.

What the longer tracks' geometry can and cannot separate

The fixed 29-track study compared predicted angular-rate patterns for every model pair using the receiver paths. It did not score the recorded gyroscope. All 29 source tasks passed; every pair/treatment result is in the table.

The median fraction of predicted contrast left after nuisance projection was:

Comparison Constant bias Bias and drift Bias, drift, gain and mount tangents
Specified-field globe vs flat 0.000991 0.0000916 0.00000000143
Specified-field globe vs zero-field globe 0.0000454 0.00000320 0.00000000383
Zero-field globe vs flat 0.000569 0.000153 0.00000000126

The calculation takes the worst crab, roll, pitch and model anchor in its declared envelope. With the widest unbounded local nuisance tangent, nearly all rate contrast can be represented by calibration/mount changes on these paths. The 12 tracks below both earlier motion reference values do not improve that result: their median retained fractions under the widest tangent are also below one part in a billion for all three pairs.

This is not a conclusion that the recorded fits are false or that no airborne IMU can distinguish the models. The original complete fit uses bounded calibration, acceleration and receiver-position constraints together. This diagnostic uses angular-rate geometry alone, uniform weights and an aircraft-motion term assumed independently removable. The data do not supply that independent body rotation. A realistic, bounded, full-pipeline design check is still required before any of these new candidates can be analyzed. No candidate is promoted, no new Earth-model fit is run, and no statistical power or significance follows from these fractions.