Receiver choice matters at the scale of the smaller force gaps

Both receivers accepted the 30-second window at 339 of 490 saved target times across eleven survey legs. All 339 windows passed the common-epoch check. The remaining 151 keep their original width dispositions. The calculation uses paired receiver measurements and no inertial data.

Trajectory order Median leg's 95th-percentile force difference Largest force difference Later gaps in the two calibration pilots
Quadratic 0.00169 m/s² 0.00455 m/s² 0.0416–0.0535 m/s²
Fourth-degree 0.00261 m/s² 0.00890 m/s² 0.00288–0.00570 m/s²

For each leg, the percentile uses the largest of the four candidates' 95th-percentile absolute force differences. The largest difference is over every candidate and supported window. The calibration gaps come from a separate two-recording study with different time supports and supply a scale comparison.

The quadratic receiver differences were well below the remaining quadratic calibration gaps. The fourth-degree differences reached the scale of the later fourth-degree gaps. This shows why a small gap under the higher-order trajectory is sensitive to receiver motion. It does not estimate the absolute error of either receiver. The signals can share satellite and processing errors, and distinct antenna positions can add real motion to the differences.

The frozen calculation preserves all eleven pair identities and original target decisions. It completed 43,392 force quadrature evaluations and 1,356 centre kinematic evaluations, with zero position solves and zero inertial fits. The force comparison remains diagnostic and supplies no calibrated shape decision.

Per-window results · All eleven pair summaries.

~/venv/bin/python analysis/tests/run_numerical.py --workers 1 --threads 1 -- \
  env PYTHONPATH=analysis ~/venv/bin/python -m lll.ilvis0_paired_receiver_force replay