Local Level Lab

Airborne measurements. Open methods.

A mounting-separation correction explains little of the recorder differences

All eight comparisons had enough motion to estimate the three displacement components. On the mixed IMU8 and IMU21 pair, the correction reduced the later one-second vector error by about 15%. At ten seconds the reduction was about 4%. On the two IMU21 recordings the change was less than 1% at either window length.

Recorder pair Window Later RMS with constant offset Later RMS with mounting correction Displacement fitted earlier
IMU8 and IMU21 1 s 0.01291 m/s² 0.01092 m/s² 23.59 m
IMU8 and IMU21 10 s 0.00185 m/s² 0.00179 m/s² 16.25 m
Two IMU21 1 s 0.002624 m/s² 0.002606 m/s² 1.52 m
Two IMU21 10 s 0.001391 m/s² 0.001393 m/s² 4.73 m

The table uses the packet-header clock. The nominal clock gives the same pattern. These are vector differences after earlier-only alignment, so their RMS values differ from the earlier magnitude-only comparison. Displacement estimates vary with averaging width even though the physical mounts are fixed. The results do not establish the distance between the mounts or an absolute sensor error. The paired comparisons leave the shape decision open.

Both tasks completed in 21.9 seconds, with 12 charged operations and nine passing software checks. The two original pairs and packet clocks are preserved. The study fits relative alignment, offsets and displacement. It makes no Earth-model fit or receiver-position comparison. Reserved flights remain unopened.