How closely do two accelerometers on the same aircraft agree?
The two IMU21 recordings agreed much more closely than the IMU8 and IMU21 recordings on the other flight. At one second, their later differences were 0.0018 and 0.0243 m/s² RMS respectively, after removing the mean difference measured earlier on each leg. Both clocks gave nearly the same result.
| Time averaged | IMU8 and IMU21 difference (m/s² RMS) | Two IMU21 recordings difference (m/s² RMS) |
|---|---|---|
| 0.05 s | 0.13488 | 0.02618 |
| 0.25 s | 0.04920 | 0.00612 |
| 1 s | 0.02430 | 0.00184 |
| 10 s | 0.00722 | 0.00017 |
| 30 s | 0.00390 | 0.00011 |
The table uses packet-header elapsed time. The common legs lasted 552 and 506 seconds. The earlier mean differences were about −0.106 and +0.0006 m/s². The one-second values use 275 and 252 later windows. The 30-second values use eight and seven. Both comparisons used the original signed accelerometer counts and excluded gyroscope measurements from the calculation. Two of two tasks passed with zero errors and zero Earth-model fits.
The measurements show how quickly between-recorder differences shrink when the data are averaged. This can help test a proposed error model. The two recorders can share errors from aircraft motion or processing. They can also differ due to calibration, timing or where they were mounted. The study leaves absolute sensor error and motion within a packet unresolved. It leaves the shape decision open.
Implications for an error model
If the recorder difference behaved as independent noise with constant variance, its RMS would scale approximately as the inverse square root of averaging time. Using the measured one-second RMS to set that scale, the mixed pair's 10-second RMS is 0.94 times the formula's value. For the two IMU21 streams it is 0.29 times that value. Their 50 ms RMS values are 1.24 and 3.18 times the formula's values, respectively. The results are similar under either clock. This is a descriptive check of the paired difference, using the later one-second result as the reference. It provides no calibrated probability and cannot separate correlated sensor errors from differences in timing or motion at the two mounts.
If both adjusted recordings are required to track the same one-second reference, at least one must differ from it by half their pairwise RMS or more. Those conditional minimum disagreements are 0.0122 and 0.00092 m/s². The comparison does not bound errors the two recorders share.
Frozen method · All timings and differences · Verified run evidence