Qualify training-only gyro-free calibration on known forces
Fit one set of three accelerometer gains, three biases and a gravity correction to earlier force magnitudes. Use the packet calibration on measured increments and time quadrature on the required force. Use the same whole-packet time support on both sides. Keep all seven fitted parameters and apply the same positive-definite force covariance to all training evaluations. Keep the later packets, target forces and scores out of training and save the calibration before opening them.
Use eight generated force records. Four use the nominal clock and four use variable elapsed intervals. The targets have an exactly integrable vertical force. The sensor directions vary between packets, with each recording sharing known gains and biases. Hold the earlier calibration fixed on later packets. Require the original numerical stop and later force RMS at most \(10^{-6}\) m/s². Require the same calibration to miss an independently altered later force of 0.025 m/s² by at least 0.024 m/s² RMS. Check forecast agreement without requiring unique parameter recovery. These controls test the software and the split.
Separately check a continuous-motion error bound against a rotating force with a known exact packet average. If body-frame force changes at no more than \(L\) m/s³ over a packet of length \(\Delta\), the variance of the force vector within that packet is at most \(L^2\Delta^2/12\). This follows by writing the variance as half the mean squared difference between two times in the packet. If the packet average vector has magnitude at least \(m\), the difference between the continuous mean magnitude and the magnitude of the averaged vector is bounded above by \(\min(L\Delta/\sqrt{12},\,L^2\Delta^2/(24m))\). For \(m=0\), use the first term. A recorded-data application would need independently supported bounds for body-frame force change, including aircraft turning. The generated tests do not establish those bounds.
Freeze two one-thread workers, eight single-start fits, 80 training residual calls per case, the solver's matching derivative and endpoint allowance, and two later checks per case. Charge work as it runs. Use a three-minute wall cap with the existing qualified task recovery, at most one technical restart per unfinished case, two interruptions total and a three-minute recovery cap. Use no archived aircraft outcomes.