Two new noise draws: bound-aware aircraft check
48/48 cases returned; 48 technical, 48 numerical and 48 withheld-position accuracy checks passed. 48 passed both required numerical and accuracy screens.
| Seed | Returned | Technical | Numerical | Accuracy | Combined |
|---|---|---|---|---|---|
| 314159 | 24/24 | 24 | 24 | 24 | 24 |
| 161803 | 24/24 | 24 | 24 | 24 | 24 |
| Seed | Physical coordinates inside bounds | Future receiver coordinates inside bounds | Median physical width, latitude / longitude / height |
|---|---|---|---|
| 314159 | 2880/2880 | 2880/2880 | 0.00078262° / 0.0006588° / 12.408 m |
| 161803 | 2880/2880 | 2880/2880 | 0.00075448° / 0.0006515° / 12.75 m |
The predeclared 48/48 method gate passed. The full per-condition table preserves every missing, failed and passing case. Interval containment and width are reported separately in that table and the verified report.
Two independent noise draws per condition are not enough to calibrate 95% interval coverage. Receiver epochs within a draw are correlated. These are generated software checks, not observed-aircraft evidence. Every scientific decision abstains. The original 24-case release and its failed stopping check remain unchanged.